آموزش فعال یا غیرفعال کردن B140i بر روی سرور DL380 Gen9
گاهی ممکن است نیاز داشته باشید تا رید کنترلر B140 که به صورت OnBoard بر روی سرور قرار گرفته است را فعال یا غیر فعال کنید . با استفاده از روش زیر میتوانید این کار را انجام دهید .
HPE Dynamic Smart Array B140i drives are not found when RAID mode is disabled
:Description
When an HPE Dynamic Smart Array B140i RAID controller is enabled on a server and RAID mode is disabled in the UEFI System Utilities, then the drives will be listed as AHCI drives or HPE H220i drives and the RAID controller is not found in POST or device manager. When RAID mode is enabled, the drives will appear as HPE Dynamic Smart Array B140i controller drives
:Action
Press F9 during the startup process to access the UEFI System Utilities
In the Systems Configuration menu, select BIOS/Platform Configuration (RBSU) > System Options > SATA Controller Options > Embedded SATA Configuration > Enable HP Dynamic Smart Array RAID support.
Press F10 to save the configuration
Reboot the server